1000W – 3000W

Low Power Fiber Laser Chiller Series

The Low Power Fiber Laser Chiller Series from HanLi is specifically designed for the efficient cooling of 1000W-3000W fiber lasers. Ideal for maintaining the optimal performance of your fiber lasers, it provides reliable and efficient cooling, backed by advanced technology and a user-centric design.

Product Features

  • Efficiency & Environmental Protection

  • Double Temperature Controls

  • Flow & Over-Temperature Alarms

  • Thermal Protection for Compressor

  • Leakage Protection Device

  • Rigorously Engineered Design

  • Easy Installation and Operation

  • Low Noise, High Lift, Large Flow, Long Lifespan

  • Corrosion-Resistant Stainless Steel Water Tank

  • Water Filters Installed in the Tank and Outlet

Environmental Requirement

  • Environment temperature: 0~45℃;

  • Relative humidity: ≤90%;

  • Elevation: ≤3000m;

The relationship between the cooling medium temperature and the ambient temperature is shown in the following picture:

Application Range

  • For cooling 1000W-3000W CW fiber lasers.

Important Specifications

Model Machine Power Current Tempe. Control Accuracy Rated Flow Max. Pump Lift Voltage & Frequency Recommended Matching
  HL-1000-QG2/2 1.8 kW 8.2 A ± 1℃ 33 L/min 36 mtr 1p 220V @50Hz 1kW CW Fiber Laser
  HL-1000-EH-QG2/2 1.9 kW 8.7 A ± 1℃ 33 L/min 36 mtr 1p 220V @60Hz 1kW CW Fiber Laser
  HL-1500-QG2/2 2.4 kW 10.9 A ± 1℃ 33 L/min 45 mtr 1p 220V @50Hz    1.5kW CW Fiber Laser
  HL-1500-EH-QG2/2 2.5 kW 11.1 A ± 1℃ 33 L/min 45 mtr 1p 220V @60Hz    1.5kW CW Fiber Laser
  HL-2000-QG2/2 3.3 kW 15 A ± 1℃ 33 L/min 45 mtr 1p 220V @50Hz 2kW CW Fiber Laser
  HL-2000-EH-QG2/2 3.5 kW 15.9 A ± 1℃ 33 L/min 45 mtr 1p 220V @60Hz 2kW CW Fiber Laser
  HL-3000-QG2/2 3.8 kW 17.3 A ± 1℃ 64 L/min 47 mtr 1p 220V @50Hz 3kW CW Fiber Laser
  HL-3000-EH-QG2/2 3.7 kW 16.8 A ± 1℃ 64 L/min 47 mtr 1p 220V @60Hz 3kW CW Fiber Laser

4000W – 6000W

Medium Power Fiber Laser Chiller Series

The Medium Power Fiber Laser Chiller Series from HanLi is specifically designed for the efficient cooling of 4000W-6000W fiber lasers. Ideal for maintaining the optimal performance of your fiber lasers, it provides reliable and efficient cooling, backed by advanced technology and a user-centric design.

Product Features

  • Efficiency & Environmental Protection

  • Double Temperature Controls

  • Flow & Over-Temperature Alarms

  • Thermal Protection for Compressor

  • Leakage Protection Device

  • Rigorously Engineered Design

  • Easy Installation and Operation

  • Low Noise, High Lift, Large Flow, Long Lifespan

  • Corrosion-Resistant Stainless Steel Water Tank

  • Water Filters Installed in the Tank and Outlet

Environmental Requirement

  • Environment temperature: 0~45℃;

  • Relative humidity: ≤90%;

  • Elevation: ≤3000m;

The relationship between the cooling medium temperature and the ambient temperature is shown in the following picture:

Application Range

  • For cooling 4000W-6000W CW fiber lasers.

Important Specifications

Model Machine Power Current Tempe. Control Accuracy Rated Flow Max. Pump Lift Voltage & Frequency Recommended Matching
  HL-4000-QG2/2 6 kW 9.3 A ± 1℃ 64 L/min 56.5 mtr 3p 380V @50hz 4kW CW fiber laser
  HL-4000-EH-QG2/2 6 kW 9.3 A ± 1℃ 64 L/min 56.5 mtr 3p 380V @60hz 4kW CW fiber laser
  HL-6000-QG2/2 7.5 kW 11.6 A ± 1℃ 64 L/min 56.5 mtr 3p 380V @50hz 6kW CW fiber laser
  HL-6000-EH-QG2/2 7.2 kW 11.1 A ± 1℃ 64 L/min 56.5 mtr 3p 380V @60hz 6kW CW fiber laser

8000W – 30000W

High Power Fiber Laser Chiller Series

The High Power Fiber Laser Chiller Series from HanLi is specifically designed for the efficient cooling of 8000W-30000W fiber lasers. Ideal for maintaining the optimal performance of your fiber lasers, it provides reliable and efficient cooling, backed by advanced technology and a user-centric design.

Product Features

  • Efficiency & Environmental Protection

  • Double Temperature Controls

  • Flow & Over-Temperature Alarms

  • Thermal Protection for Compressor

  • Leakage Protection Device

  • Rigorously Engineered Design

  • Easy Installation and Operation

  • Low Noise, High Lift, Large Flow, Long Lifespan

  • Corrosion-Resistant Stainless Steel Water Tank

  • Water Filters Installed in the Tank and Outlet

Environmental Requirement

  • Environment temperature: 0~45℃;

  • Relative humidity: ≤90%;

  • Elevation: ≤3000m;

The relationship between the cooling medium temperature and the ambient temperature is shown in the following picture:

Application Range

  • For cooling 8000W-30000W CW fiber lasers.

Important Specifications

Model Machine Power Current Tempe. Control Accuracy Rated Flow Max. Pump Lift Voltage & Frequency Recommended Matching
  HL-8000-QG2/2 9.5 kW 14.7 A ± 1℃ 130 L/min 65 mtr 3p 380V @50hz 8kW CW fiber laser
  HL-12000-QG2/2 13 kW 20.1 A ± 1℃ 150 L/min 65 mtr 3p 380V @50hz   12kW CW fiber laser
  HL-15000-QG2/2 15 kW 23.3 A ± 1℃ 150 L/min 65 mtr 3p 380V @50hz   15kW CW fiber laser
  HL-20000-QG2/2 20 kW 32 A ± 1℃ 200 L/min 60 mtr 3p 380V @50hz   20kW CW fiber laser
  HL-30000-QG2/2 32 kW 45 A ± 1℃ 300 L/min 42 mtr 3p 380V @50hz   30kW CW fiber laser